Connect, no.131, July/August 2004, p.3

One of two horizontal 60t capacity axial fatigue testing machines designed for the project. They are used for the strip testing programme in sour environments
One of two horizontal 60t capacity axial fatigue testing machines used for the strip testing programme in sour environments

Eight countries - fourteen companies - budget US$1.4M

Extensive investigations have been carried out by TWI into the fatigue behaviour of welded C-Mn steel catenary risers (SCRs) over the last decade resulting in guidance rules for fatigue design. In the case of corrosive and sour products, knowledge of the performance of welded joints in both C-Mn steel and corrosion resistant alloy (CRA) in such environments is needed. This is particularly important in the development of high pressure, high temperature (HP/HT) deepwater and mildly sour fields. However, there is little information concerning fatigue performance of C-Mn steel or CRA in sour conditions.

TWI is running a major Joint Industry Project to develop fatigue test data for a range of materials in a variety of corrosive environments. The project is currently supported by fourteen major operators, fabricators and material suppliers from eight countries and has a total budget of US$1.4M.

The project is scheduled for completion by mid 2005 when preliminary guidelines on the fatigue design of C-Mn steels and corrosion resistant SCR girth welds in mildly sour conditions will be produced.

For further details and how to participate, contact Reza Razmjoo.
E-mail: reza.razmjoo@twi.co.uk

Copyright © 2004 TWI Ltd
Information and advice from TWI and its partners are provided in good faith and based, where appropriate, on the best engineering knowledge available at the time and incorporated into TWI's website in accordance with TWI's ISO 9001:2000 accredited status. No warranty expressed or implied is given regarding the results or effects of applying information or advice obtained from the website, nor is any responsibility accepted for any consequential loss or damage.