Equipment for Oxyacetylene WeldingEssential equipment componentsTorchThe basic oxyacetylene torch comprises:
NB The cutting torch requires two oxygen supplies to the nozzle, one mixed with fuel gas for preheating and a separate oxygen flow for cutting. HosesHoses between the torch and the gas regulators should be colour-coded; in the UK: red for acetylene, and blue for oxygen. Fittings on the oxygen hose have right-hand threads; while those on the acetylene hose have left-hand threads. Gas regulatorsThe primary function of a gas regulator is to control gas pressure. It reduces the high pressure of the bottle-stored gas to the working pressure of the torch, and this will be maintained during welding. The regulator has two separate gauges: a high pressure gauge for gas in the cylinder and a low pressure gauge for pressure of gas fed to the torch. The amount of gas remaining in the cylinder can be judged from the high pressure gauge. The regulator, which has a pressure adjusting screw, is used to control gas flow rate to the torch by setting the outlet gas pressure. Note Acetylene is supplied in cylinders under a pressure of about 15 bar but welding is carried out with torch gas pressures typically up to 2 bar. Flame trapsFlame traps (also called flashback arresters) must be fitted into both oxygen and acetylene gas lines to prevent a flashback flame from reaching the regulators. Non-return spring-loaded valves can be fitted in the hoses to detect/stop reverse gas flow. Thus, the valves can be used to prevent conditions leading to flashback, but should always be used in conjunction with flashback arresters. A flashback is where the flame burns in the torch body, accompanied by a whistling sound. It will occur when flame speed exceeds gas flow rate and the flame can pass back through the mixing chamber into the hoses. Most likely causes are: incorrect gas pressures giving too low a gas velocity, hose leaks, loose connections, or welder techniques which disturb gas flow. Identification of gas cylindersGas cylinders are colour-coded. In the UK, an oxygen cylinder is black; and an acetylene cylinder is maroon. Cylinders should also carry a label that gives details of the type of gas. NB Colour coding of gas cylinders is being changed to comply with BSEN 1089-3:2004 Transportable Gas Cylinders - Cylinder Identification Part 3 Colour coding. In this standard oxygen cylinders will be identified with a white shoulder. In the UK, acetylene cylinders will continue to be identified with a maroon body and shoulder. Oxygen and acetylene are stored in cylinders at high pressure. Oxygen pressure can be as high as 230 bar. Acetylene, which is dissolved in acetone contained in a porous material, is stored at a much lower pressure, approximately 15 bar. The appropriate regulator must be fitted to the cylinders to accommodate cylinder pressures. To avoid confusion, oxygen cylinders and regulators have right-hand threads, but acetylene cylinders and regulators have left-hand threads. Typical gas pressures and flow rates for C-Mn steel:
Selection of correct nozzlesWelding torches are generally rated according to thickness of material to be welded. They range from light duty (for sheet steel up to 2mm in thickness) to heavy duty (for steel plate greater than 25mm in thickness). Each torch can be fitted with a range of nozzles with a bore diameter selected according to material thickness. Gas pressures are set to give correct flow rate for nozzle bore diameter. Proportions of oxygen and acetylene in the mixture can be adjusted to give a neutral, oxidising or carburising flame. (See the description of oxyacetylene processes) Welding is normally carried out using a neutral flame with equal quantities of oxygen and acetylene. Equipment safety checksBefore commencing welding it is wise to inspect the condition and operation of all equipment. As well as normal equipment and workplace safety checks, there are specific procedures for oxyacetylene. Operators should verify that:
It is recommended that oxyacetylene equipment is checked at least annually - regulators should be taken out of service after five years. Flashback arresters should be checked regularly according to manufacturer's instructions and, with specific designs, it may be necessary to replace if flashback has occurred. For more detailed information the following legislation and codes of practice should be consulted:
For further information contact arc@twi.co.uk
Copyright ©2007 TWI Ltd | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Information and advice from TWI and its partners are provided in good faith and based, where appropriate, on the best engineering knowledge available at the time and incorporated into TWI's website in accordance with TWI's ISO 9001:2000 accredited status. No warranty expressed or implied is given regarding the results or effects of applying information or advice obtained from the website, nor is any responsibility accepted for any consequential loss or damage.
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||