Teletest® long range UT inspection of jetty lines for Shell

The jetty lines penetrating the sea-wall
Jetty lines penetrating the sea-wall
This programme involved the inspection of eight lines of 4", 6", 8" and 12" diameter, where they passed through the 0.8-1.0m thick sea wall at the Shell Haven Refinery. Inspection was possible from both sides of the wall. Thus the required transmission range was small in comparison to other projects. A feature of this project is that the pipes had a bitumastic wrapping. Such wrappings can lead to rapid attenuation of the ultrasound. Despite these reservations, in this case the technique performed successfully, partly because the required test range was so limited and partly because the wrapping was old and no longer strongly adherent.

Copyright © 2001, TWI Ltd

Search for related content 
Information and advice from TWI and its partners are provided in good faith and based, where appropriate, on the best engineering knowledge available at the time and incorporated into TWI's website in accordance with TWI's ISO 9001:2000 accredited status. No warranty expressed or implied is given regarding the results or effects of applying information or advice obtained from the website, nor is any responsibility accepted for any consequential loss or damage.