A-TIG for welding of stainless steels

Without activated flux
The conventional TIG process and weld profile Conventional TIG weld


With activated flux
The A-TIG process and weld profile A-TIG weld

Activated-flux TIG (A-TIG) enables single pass low distortion welding of stainless steels in a section depth widely used for nuclear waste containment.

The activated flux is applied prior to welding and produces a narrower deeper TIG weld.

Benefits

  • Shorter welding times
  • Reduced consumption of filler wire
  • Elimination of back-gouging and/or grinding
  • Reduced distortion
  • Reduced susceptibility to cast-to-cast variations in weld penetration
  • Activated fluxes give increased penetration in steels
  • Flux applied by spray, paste or brush applicator
TWI has carried out extensive investigations into the use of A-TIG. Facilities are available to allow member companies to explore the use of A-TIG in their applications.


For further information, please contact: power@twi.co.uk

Copyright © 2001, TWI Ltd

Information and advice from TWI and its partners are provided in good faith and based, where appropriate, on the best engineering knowledge available at the time and incorporated into TWI's website in accordance with TWI's ISO 9001:2000 accredited status. No warranty expressed or implied is given regarding the results or effects of applying information or advice obtained from the website, nor is any responsibility accepted for any consequential loss or damage.