Plant Integrity Ltd has launched the latest version of the Teletest Focus+ Guided Wave Pulser-receiver unit. This system will replace the successful Teletest Focus unit.

The development of the Teletest Focus+ unit has taken 2 years of collaboration between Plant Integrity, key industrial partners and TWI’s Long Range Ultrasonics Group in order to provide a pulser-receiver unit that not only improves Guided Wave inspection for site technicians but also provides the optimum platform for Guided Wave Research and development for TWI and other Institutes.

The key improvements to the pulser-receiver unit are Ethernet communications and 24 fully independent transmit and receive channels to speed up data collection. Better range and sensitivity has been achieved due to maintaining the Teletest standard output voltage of 300V Peak to Peak with improved sampling resolution and filtering.

Weight has not been compromised for this added functionality with a 45% reduction to 8kg over the previous unit.

Key features introduced in the previous pulser-receiver unit such as the internal electric pump for inflation of collars and GPS have proved so popular that they have been kept within the new unit also. Inspection of pipelines is still operated in octants to fully utilise the A-Map (unrolled pipe) and secondary focussing technique unique to Teletest.

WaveScan Data
WaveScan Data

WaveScan Data

The Teletest Focus+ system is fully back compatible with tooling and Teletest WaveScan software. Teletest operates in Multimode configuration as standard uniquely providing both longitudinal and torsional wavemode inspection simultaneously. In addition, a new five ring Torsional module has been launched that provides a high amplitude, broad frequency range torsional inspection when that additional power is required, without the need to change transducer spacing.

For further information read about asset integrity management at Plant Integrity Ltd or contact us.

Teletest Focus+ Technical Specification

Standard Output Voltage

300V peak to peak

Number of transducer Channels

80

Maximum number of averages

1,000,000

Maximum Sample Range

1000ms

Receiving gain range

1-120dB in 1dB steps

Teletest Focus+ weight

8kg

Teletest Focus+ Dimensions

33x33x14cm

Run time on battery

10 hours typical

Screen

OLED Display

Communication Protocol

Ethernet

Supported Operating systems

Windows XP, 7

Automated Self checking

Standard

Integrated Air Pump

Standard